EasyManua.ls Logo

Brother HL-4570CDW - Page 103

Brother HL-4570CDW
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-72
Confidential
Error code C6
Pressure engagement/disengagement failure of toner cartridge.
Error code C7
Insufficient memory.
<User Check>
- Delete the stored data.
- Install additional DIMM.
Error code C8
RAM area for secure data full.
<User Check>
- Delete the stored data.
- Limit the registration of secure files within the limit of 10 users and 3 jobs.
Toner Error
One or more Toner Cartridges are not detected. Pull out and reinsert all 4
Toner Cartridges.
Step Cause Remedy
1 Harness connection failure of
develop release motor
Check the harness connection of the
develop release motor and
reconnect it.
2 Develop release motor failure Replace the develop release motor.
3 Develop release sensor PCB
ASSY failure
Replace the develop release sensor PCB
ASSY.
4 Engine PCB failure Replace the engine PCB ASSY.
Out of Memory
Add more Memory.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Out of Memory
Secure Print Data is full. Press Cancel and delete the previously stored
data.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.