■ Switching of timing to execute Auto Registration
<Function>
Relative displacement between Cyan, Magenta, Yellow, and Black is detected using the
registration mark sensor, and the Auto Registration is executed at the timing when the
displacement value exceeds the stipulated threshold value.
This function is to switch the threshold value which is used as the timing to execute Auto
Registration. The threshold value can be switched in three phases between High, Mid, and
Low.
“*” is displayed at the end of the currently specified function in the LCD display.
<Operating procedure>
LCD Description
Regi Freq=Mid The frequency to execute Auto Registration is middle. (default)
Regi Freq=High The frequency to execute Auto Registration is high.
Regi Freq=Low The frequency to execute Auto Registration is low.
Note:
It can be set regardless of the Auto Registration switching function in the function menu.
Even if this function is switched, it does not affect the timing to execute Auto Registration in
the function menu.
Model without touch panel
Model with touch panel
(1) Press the or key to display
“MAINTENANCE 45” on the LCD in the
initial state of the maintenance mode.
Then, press the OK key. “USBNo.” is
displayed on the LCD.
(2) Press the or key to display
“Regi Freq” and then press the OK or
Go key.
(3) Press the or key to select
“Regi Freq=Mid”, “Regi Freq=High” or
“Regi Freq=Low”, and press the OK or
Go key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial
state of the maintenance mode.
(1) Press the 4 and 5 keys in this order in
the initial state of the maintenance
mode. “USBNo.” is displayed on the
LCD.
(2) Press the or key to display
“Regi Freq” and then press the Mono
or SET key.
(3) Press the or key to select
“Regi Freq=Mid”, “Regi Freq=High” or
“Regi Freq=Low”, and press the Mono
or SET key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial