5-28
Confidential
■ Change of ghost reduction setting
<Function>
This function is a mode to reduce the level of ghost when it appears in low temperature and
high humidity environment. If this function is turned ON, however, spots and dirt may appear
on print.
“*” is displayed at the end of the currently specified function in the LCD display.
<Operating procedure>
LCD Description
ON Turn ON the ghost reduction function.
OFF Turn OFF the ghost reduction function. (default)
Model without touch panel
Model with touch panel
(1) Press the or key to display
“MAINTENANCE 45” on the LCD in the
initial state of the maintenance mode.
Then, press the OK key. “USBNo.” is
displayed on the LCD.
(2) Press the or key to display
“Ghost Reduction” and then press the
OK or Go key.
(3) Press the or key to select “ON”
or “OFF”, and press the OK or Go key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial
state of the maintenance mode.
(1) Press the 4 and 5 keys in this order in
the initial state of the maintenance
mode. “USBNo.” is displayed on the
LCD.
(2) Press the or key to display
“Ghost Reduction” and then press the
Mono or SET key.
(3) Press the or key to select “ON”
or “OFF”, and press the Mono or SET
key.
(4) “Accepted” is displayed on the LCD,
and the machine returns to the initial
state of the maintenance mode.