Brother PJ-600/700/800 Series Command Reference
© 2015 Brother Industries, Ltd. All Rights Reserved.
5.2. Command details
Skip
If data transmission should be stopped midway, send the “initialize” command after
sending the “invalid” command for the appropriate number of bytes to return to the
receiving state, where the print buffer is cleared.
ESC + i + a + {n1}
1B H + 69 H + 61 H + {n1}
Switches between the machine's command modes. A machine that receives this
command operates in the specified command mode until the machine is turned off.
Definition of {n1}:
0:ESC/P・Raster (default)
1: Maintenance Mode
3:P-touch Template
Initializes the print buffer.
Status information request
ESC + i + S
1B H + 69 H + 53 H
Status information is transmitted.
ESC + ~ + p + {n1} + null
1B H + 7E H + 70 H + {n1} + 00 H
Specifies whether or not the strobe time is extended and the print density is adjusted
when 2-ply paper is used.
Definition of {n1}:
0: Disable (default)
1: Enable