87
ELECTRICAL
ELECTRIC STARTER SYSTEM
4
Check for continuity across magnetic switch “S”
terminal and “M” terminal.
If no continuity, replace coil.
Check for continuity across magnetic switch “S”
terminal and coil case.
If no continuity, replace coil.
Place plunger against a flat surface and push the
magnetic switch down. With switch held down,
check for continuity between terminal “B” and ter-
minal “M.”
If no continuity, replace the magnetic switch and/
or plunger.
1. “S” terminal
2. “M” terminal
3. “B” terminal
004771
004772
004773