ELECTRICAL
ELECTRIC STARTER SYSTEM
No-Load Performance Test
Connect battery and ammeter to starter motor as
shown:
Check that starter rotates smoothly and steadily
with pinion moving out.
Check that ammeter indicates 90 A at 11 V.
Installation
Installation is reverse order of removal with spe-
cial attention to the following steps:
Place starter motor in position, then install two
dowel pins and motor bracket.
Tighten starter and bracket screws to 16.5 ft. lbs.
(23 N·m).
Check wire routing. Refer to WIRE ROUTING on
p. 229.