8. Ins
tallation and connection of the RAVE control unit
¿ Note: The hose package of the RAVE control is already pre-assembled.
¿ Note: The impulse restrictor is offered optionally.
Insert impulse nozzle (pos. 6) about 25 mm into the 420 mm pressure line (pos. 7)
using an Allen key SW4. Pay attention to the mounting direction! It also works
without an impulse nozzle, this only serves to delay the opening of the exhaust
valve.
¿ Note: In order to prevent the displacement of the impulse nozzle (pos. 6), a small tie wrap
(pos. 8) should be attached to the pressure line directly afterwards. Do not tie up the
pressure line completely.