BRP-Rotax
INSTALLATION MANUAL
Positive
terminal
916 i TYPE C24
Interface Parameter Min.
Max. Nominal
Input voltage: 24 V
Input load:*
* for resistance of starter circuit
Rsmax = <20 mOhm
20 A 350 A
5
The terminal must be conducted as M5 screw connection suitable for cable lug according
to DIN 46225.
Tightening torque: Min. 3 Nm (27 in.lb) Max. 5 Nm (44 in.lb).
Negative terminal The engine block must be connected to the airframe using a properly sized ground strap
(minimum the same cable cross section as the starter supply), for carrying the starter cur-
rent and to avoid static electricity between the engine and the airframe.
Effectivity: 916 i A / C24
Edition 0/Rev. 1
80–00–00
Page 5
December 01 2023
5. When electric starter is activated