SELECTIVITY:
RANGE:
FILTER CONTROL
MODE
:
OUTPUT:
2.2.
REAR
PANEL
CHASSIS-SIGNAL
GROUND
:
10
a
separate
ground
terminal.
The
maximum
input
voltage
is 5 V,
and
the
impedance
is 1
MO
in
parallel
with
100
pF.
A
three-position
switch
that
selects
the
bandwidth
of
the
filters
,
and
the
centre
frequency
step
length
for
full-octave
scanning
.
Functions
are
as
follows:
Upper
position:
third-octave
bandwidth
with
scanning
in
third-octave
steps.
Middle
position:
full-octave
bandwidth
with
scanning
in
third-octave
steps,
with
overlapping
.
Lower
position:
full-octave
bandwidth
with
scanning
in
full-octave
steps.
A
three-position
switch
to
select
the
narrow
band
ranges,
or
"Linear",
for
both
manual
and
recorder
controlled
operation
.
Functions
are as
fol-
lows
:
Upper
position:
"Linear"
range
from
1 Hz to 1
80
kHz,
independent
of
the
position
of
the
MANUAL
FILTER SELECTOR .
Middle
position:
"2
Hz
to
160
kHz"
,
filters
are
selected
automatically
,
or
by
the
MANUAL
FILTER SELECTOR
from
the
inner
scale on
the
MANUAL
FILTER SELECTOR.
Lower
position:
"2
Hz
to
40
kHz-D-A-B-C-Lin
.",
filters
are
selected
au-
tomatically,
or
by
the
MANUAL
FILTER SELECTOR
from
the
outer
scale
on
the
MANUAL
FILTER SELECTOR .
Two
switches
that
control
how
the
filters
are
selected,
plus
two
LED
in-
dicators
,
one
to
show
whether
the
instrument
is
in
operation
under
manual
control,
and
the
other
indicating
that
all
front
panel
controls
are
inactive
while
the
i
nstrument
is
being
controlled
via
the
Digital
In-
terface
.
The
left-hand
switch
can
select
"Manual
" so
that
the
filters
are
chosen
by
the
MANUAL
FILTER SELECTOR and
start
of
Recorder read-
out
is
impossible,
or
it
can
select
"Recorder"
mode
allowing
filter
selec-
tion
to
be
made
by
extern
a I
control
.
The
right
-
hand
switch
enables
the
Recorder
in
use
to
be
controlled
from
the
Band
Pass
Filter
.
This
facility
is blocked
when
"Manual"
has
been
selected,
or
when
control
is
being
exercised via
the
Digital
Inter-
face .
Two
LEOs
light
to
indicate
whether
"Stop"
or
"Run"
is
selected
.
Standard
B & K coaxial
socket,
fitting
JP
0101
Plugs,
paralleled
by a
BNC socket on
the
rear
panel.
There
is a
separate
ground
terminal.
Im-
pedance less
than
200,
minimum
load
impedance
50
in
parallel
with
1 nF.
A
pair
of
clamping
terminals
with
a
shorting
strap
permits
the
signal
ground
to
be
connected
to
the
instrument
chassis
.