Loading...
BN1100 Revision: 0 Initial Issue: 21/08/2012
ATA 31-10-04
Insulation Resistance >100
Dielectric Strength 500 Vdc
Signal Ground Isolated from housing
Connection Through a bifilar cable (double-shielded recommended)
Single-shielded possible if connected to structure in both ends
Environmental Characteristics
Temperature Normal Operational Range 51°C to +150°C
Temperature Survival Range 55°C to +150°C
Max. Operating Sinusoidal Vibration 500 g
Max. Shock Level (peak)
(Max. Non-destructive Shock (peak))
±5000 g pk (half sine, 1 ms)
Humidity Hermetically sealed
Physical Characteristics
Dimensions See outline drawings in Fig. 2
Weight <35 gram
Case Material Stainless steel AISI 316–LS
Connector GLENAIR type 8070-1072Z15-3CN
Mounting Centre bolt
Mounting Screw (optional accessory) DIN 912 M4×18 (with safety wire hole)
According to SPX902A0002A01
Environmental Constraints
According to DO160E
Marking
Supplier Name, NATO code, p/n, S/N, Date and Measurement axis (1)
Calibration chart
Acceptance test summary report
Included Deliverables
Certificate of conformance
All values are typical at 25°C unless measurement uncertainty is specified.
The document reference is online, please check the correspondence between the online documentation and the printed version.