PULSE Multi-analyzer System Type 3560-B/C/D/E Installation and IDAe Hardware48
4.2 Overview of Hardware
Fig.4.1 Hardware available for a PULSE measurement system
020195/9
3109 3110 UA-1365
3560-C
Portable Power
Supply Unit 2827
LAN
Battery
status
On/Off
Follow/Ext. power
Battery
status
Ext. Power
10-32V
!
Single Front-end
AO-1449 (1m)
3560-C
3560-D
3560-E
3560-D
3560-E
Standard Modules for 3560-C, D, E
Power-Supply Module
Type 2826
Error
Brüel
B
K
7/6-'89
&Kjær
On/Off
Ext. Supply
Live Fuse 10 A
Ground Fuse 10 A
Ext. Supply
Follow Ext. Power
!
10-32V
Enclosure KK-0050
Power Supply 2826
Rack Mounting WU-0516
Power Supply 2826
BNC Cable
AO-0087 (1.2m)
Battery
status
On/Off
Follow/Ext. power
Battery
status
Ext. Power
10-32V
!
Power-Supply Module
Type 2826
Error
Brüel
B
K
7/6-'89
&Kjær
On/Off
Ext. Supply
Live Fuse 10 A
Ground Fuse 10 A
Ext. Supply
Follow Ext. Power
!
10-32V
BNC T-Connector
JJ-0152
BNC Cable
AO-0087 (1.2m)
Ethernet
Switch
UL-0190
PC
LAN
4 × AO-1450 (2m)
LAN
AO-1450
(2m)
Power AQ-0643
4/2-ch.
Input/Output Module
Type 3109
3 4
1 2
Input
Input
Output 2
Output 1
Measuring
Stop
Overload
25kHz
25kHz
Brüel
Brüel
B
K
7/6-'89
7/6-'89
&
Kjær
Kjær
Brüel
B
K
7/6-'89
&Kjær
2/1-ch.
Input/Output Module
Type 3110
Measuring
Overload
25kHz
Brüel
B
K
7/6-'89
&Kjær
Monitor
Input
12
Output
Power-Supply Module
Type 2826
Error
Brüel
B
K
7/6-'89
&Kjær
On/Off
Ext. Supply
Live Fuse 10 A
Ground Fuse 10 A
Ext. Supply
Follow Ext. Power
!
10-32V
Ext.
Int.
Clock In
Aux.
I/O
Sync. In
Clock Out
Sync. Out
Rx
Tx
LAN
RS-232
LAN Interface Module
Type 7533
!
Input 0
Error
Clock
Sync.
Power on/off Control
On
Off
10Mbit
10Mbit
Brüel
Brüel
B
K
7/6-'89
7/6-'89
&
Kjær
Kjær
25kHz
Brüel&
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
B
K
7/6-'89
Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
Brüel&
5
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
B
K
7/6-'89
Kjær
Input
1
2
Tacho
Input
3
4
Input
6
Brüel&
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
B
K
7/6-'89
Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
4/2-ch.
Input/Output Module
Type 3109
3 4
1 2
Input
Input
Output 2
Output 1
Measuring
Stop
Overload
25kHz
25kHz
Brüel
Brüel
B
K
7/6-'89
7/6-'89
&
Kjær
Kjær
Power-Supply Module
Type 2826
Error
Brüel
B
K
7/6-'89
&Kjær
On/Off
Ext. Supply
Live Fuse 10 A
Ground Fuse 10 A
Ext. Supply
Follow Ext. Power
!
10-32V
Ext.
Int.
Clock In
Aux.
I/O
Sync. In
Clock Out
Sync. Out
Rx
Tx
LAN
RS-232
LAN Interface Module
Type 7533
!
Input 0
Error
Clock
Sync.
Power on/off Control
On
Off
10Mbit
10Mbit
Brüel
Brüel
B
K
7/6-'89
7/6-'89
&
Kjær
Kjær
25kHz
Brüel&
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
B
K
7/6-'89
Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
Brüel
&
5
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
B
K
7/6-'89
Kjær
Input
1
2
Tacho
Input
3
4
Input
6
Brüel&
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
B
K
7/6-'89
Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
6/1-ch.
Input/Output Module
Type 3560E
Measuring
Output
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1
2
Tacho
Input
3
4
Input
5
6
4/2-ch.
Input/Output Module
Type 3109
3 4
1 2
Input
Input
Output 2
Output 1
Measuring
Stop
Overload
25kHz
25kHz
Brüel
Brüel
B
K
7/6-'89
7/6-'89
&
Kjær
Kjær
PC
Aux. I/O
Rx
RS-232
5/1 ch. Input/Output
Controller Module Type 7537A
!
Output 1
100Mbit
Brüel
B
K
7/6-'89
&Kjær
Tacho
Multi Frame Control
No
Yes
First or Last Frame
Tx LAN
Input
All Sockets
Cable Lock
1
1
2
3
4
5
Aux. I/O
Rx
RS-232
5/1 ch. Input Output
Controller Module Type 7537
!
Output 1
100Mbit
Brüel
B
K
7/6-'89
&Kjær
Tacho
Multi Frame Control
No
Yes
First or Last Frame
Tx LAN
Input
All Sockets
Cable Lock
1
1
2
3
4
5
12-ch.
Input Module
Type 3038
Measuring
25kHz
Brüel
B
K
7/6-'89
&Kjær
Tacho
1
2
3
4
5
6
Tacho
12
11
10
9
8
7
12-ch.
Input Module
Type 3038B
Measuring
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1-6
1
2
10
9
8
7
1
2
3
4
5
6
11
Input
7-12
6-ch.
Input Module
Type 3039
Measuring
25kHz
Brüel
B
K
7/6-'89
&Kjær
Tacho
1
2
3
4
5
6
6-ch.
Input Module
Type 3039B
Measuring
25kHz
Brüel
B
K
7/6-'89
&Kjær
Input
1-6
1
2
3
4
5
6
7537
7539
7537-A
7539-A
3038 3038-B 3039
3040 3041
3039-B
3040-B 3041-B
7536
7538
7540
7538-A
7540-A
LAN Interface Module
Type 7536
100Mbit
100Mbit
Brüel
Brüel
B
K
7/6-'89
7/6-'89
&
Kjær
Kjær
3560-B
Aux. I/O
Rx
RS-232
5/1 ch. Input/Output
Controller Module Type 7537A
!
Output 1
100Mbit
Brüel
B
K
7/6-'89
&Kjær
Tacho
Multi Frame Control
No
Yes
First or Last Frame
Tx LAN
Input
All Sockets
Cable Lock
1
1
2
3
4
5
Aux. I/O
Rx
RS-232
5/1 ch. Input/Output
Controller Module Type 7537A
!
Output 1
100Mbit
Brüel
B
K
7/6-'89
&Kjær
Tacho
Multi Frame Control
No
Yes
First or Last Frame
Tx LAN
Input
All Sockets
Cable Lock
1
1
2
3
4
5
BNC T-Connector
JJ-0152
3560-B
Multiple Front-ends
Controller Modules Input/Output Modules
Blank
Module
Standard 3560-B
Aux. I/O
Rx
RS-232
5/1 ch. Input/Output
Controller Module Type 7537A
!
Output 1
100Mbit
Brüel
B
K
7/6-'89
&Kjær
Tacho
Multi Frame Control
No
Yes
First or Last Frame
Tx LAN
Input
All Sockets
Cable Lock
1
1
2
3
4
5
Aux. I/O
Rx
RS-232
5/1 ch. Input/Output
Controller Module Type 7537A
!
Output 1
100Mbit
Brüel
B
K
7/6-'89
&Kjær
Tacho
Multi Frame Control
No
Yes
First or Last Frame
Tx LAN
Input
All Sockets
Cable Lock
1
1
2
3
4
5
3560-B-010
3560-B-030
3560-B-020
3560-B-040
3560-B-110
3560-B-130
3560-B-120
3560-B-140
100Mbit
LAN
Tx
5/1 ch. Input / Output
Controller Module Type 7538A
Rx
RS-232
Cable Lock
!
All Sockets
Aux. I/O
Input
5
4
3
2
1
1
Multi Frame Control
No
Yes
First or Last Frame
Output 1
Tacho
Brüel & Kjær
25kHz
Measuring
1
2
3
4
5
6
12-ch Input Module
Type 3040B
Input
1-6
12
11
10
9
8
7
Input
7-12
Brüel & Kjær
25kHz
Measuring
1
2
3
4
5
6
6-ch Input Module
Type 304 1B
Input
1-6
Brüel & Kjær
LAN
Tx
Rx
RS-232
Cable Lock
!
All Sockets
Aux. I/O
Input
5
4
3
2
1
Multi Frame Control
No
Yes
First or Last Frame
Output Tacho
Ext Po
wer
Batt
ery
sta
tus
10 to 32v
Brüel & Kjær
O
n
/
O
f
f
Battery s
ta
tus
Follow
E
xt.
Power
AUX
Power
Off On
LAN
Tx
Rx
RS-232
Cable Lock
!
All Sockets
Aux. I/O
Input
5
4
3
2
1
Multi Frame Control
No
Yes
First or Last Frame
Output
Tacho
O
n
/
O
f
f
Battery s
ta
tus
Follow E
xt.
Power
AUX
Power
Off On
Ext Po
wer
Battery
status
10 to 32v
Brüel & Kjær
100Mbit
LAN
Tx
5/1 ch. Input / Output
Controller Module Type 7538
Rx
RS-232
Cable Lock
!
All Sockets
Aux. I/O
Input
5
4
3
2
1
1
Multi Frame Control
No
Yes
First or Last Frame
Output 1
Tacho
Brüel & Kjær
25kHz
Measuring
1
2
3
4
5
6
6 ch. Input Module
Type 3041
Brüel & Kjær
25kHz
Measuring
7
8
9
10
11
12
12 ch. Input Module
Type 3040
Tach o
1
2
3
4
5
6
Brüel & Kjær
Dyn-X Modules for 3560-C, D, E
Controller Modules Input/Output Modules
Dyn-X 3560-B
3035
Charge
Input
25kHz
Measuring
7
8
9
10
11
12
12 ch. Input Module
Type 304 0
Tach o
1
2
3
4
5
6
Brüel & Kjær

Table of Contents