EN
24.7.2 Radial Vibration with Smax
Typical uses: Applications where the Smax measurement is used (ISO 7919-5, VDI 2059).
Measurement Description
Default or
Maximum Orbit displacement calculated using an XY probe pair.
DC sensor Gap voltage for diagnostics.
1X amplitude
A synchronous amplitude and phase measurement at running speed.
Requires PT
2X amplitude
A synchronous amplitude and phase measurement at twice running
speed.
Requires PT
24.8 Reciprocating Machines
24.8.1 Recip Crankcase Velocity
Typical uses: Reciprocating Compressors
Direct
Similar to the standard Velocity channel except that Fault
events are valid for alarming. This allows the channel to
alarm in the event that a liquid slug causes an excessive
1X amplitude
A synchronous amplitude and phase measurement at
running speed.
Requires PT
2X amplitude
A synchronous amplitude and phase measurement at twice
running speed.
Requires PT
DC sensor bias voltage for diagnostics.
24.8.2 Recip Cylinder Pressure
Typical uses: Measurement of rod loads, pressure/volume curves for reciprocating compressors.
Measurement Description Default or Add
Compression
Ratio of suction and discharge pressures.
Discharge
Pressure measured at the discharge.
Maximum
Highest pressure measured over a cycle.
Minimum
Lowest pressure measured over a cycle.
Peak Rod
Maximum compressive rod load measured over a cycle.
Peak Rod
Maximum tensile rod load measured over a cycle.
Rod Reversal
Number of degrees of the cycle when the rod load was
reversed.
Suction
Pressure measured at the inlet.