EasyManua.ls Logo

BRUEL & KJAER VIBROCONTROL 8000 - Remote Connection (Ethernet)

BRUEL & KJAER VIBROCONTROL 8000
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Brüel & Kjaer Vibro S1079330.002 / V04 Page 77 of 188
Technical alterations reserved!
Brüel & Kjaer Vibro Instruction
VC-8000 MPS
Content
EN
11.2 Remote Connection (Ethernet)
Remote (Ethernet) connection to the rack uses the CMS ethernet port, and the CMS IP address. The
remote connection feature must be licensed, configured, and
enabled (see section 11.6).
To connect remotely:
Start MPS Setup software
Select File, Remote Connect
Select a recent connection or enter the rack (CMS port) IP
Address.
Select the account: Administrator (to configure) or User
(View Only).
Enter the password.
Select OK
After the connection is established you can then open MPS
Maintenance software and you will be automatically connected.
To disconnect remotely use MPS Setup Software:
Select File, Remote Disconnect
11.2.1 Troubleshooting Remote Connection
Local access will be required to troubleshoot remote connection problems.
Follow the steps in section 11.6 to verify remote connection settings.
Simplify the network. Use an ethernet cable to connect your laptop directly to the CMS port to
verify that the VC-8000 remote connection is working.
11.2.2 I Forgot My Password
See section 23.9 Password Reset
11.2.3 Simultaneous Connections (Local and Remote etc.)
The software does not prevent different users from making simultaneous remote connections to the
MPS rack. For example, a scenario with one user connected local (via USB) and a second user
connected remotely (via ethernet) is possible. Likewise, two (or more) users connected remotely (via
ethernet) is also possible.
Figure
11-2) Remote Connect Dialogue

Table of Contents