Tab. 9 Overalls setup parameters
High-pass [B] e.g. 10 Hz
High-pass limit fre-
quency for path B
(range depends on
input channel setting).
Low-pass [B] e.g. 1000 Hz
Low-pass limit fre-
quency for path B
(range depends on
input channel setting).
Max X/Y On; Off
Acquisition Max X/Y.
(Depends on input
channels).
Record Mode Inactive; f(n); f(t)
Activation of overalls
versus speed f(n) or
time f(t).
Record Mode
> active f(n)
N/A
Direction
Coastdown;
Runup; Manual
Change in machine
condition
Minimal Speed e.g. 600 rpm
Definition of data
acquisition from/to
speed…
Maximal
Speed
e.g. 1500 rpm
Definition of data
acquisition from/to
speed…
Record Mode
> active f(t)
N/A
Time Unit sec; min; hours
Time unit for the mea-
surement.
Record Time e.g. 5 min Recording period.
Time Interval e.g. 1 sec
Time interval of data
recording.
Parameter
Setting para-
meter
Explanation of the
parameter