EasyManua.ls Logo

BRUEL & KJAER VIBROPORT 80 - FFT-Analyzer

BRUEL & KJAER VIBROPORT 80
131 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Translation of the Original Operating Instructions
VP-80/VP-80 E
104
9.4 FFT-Analyzer
Parameter
Setting para-
meter
Explanation of para-
meter
Input Chan-
nels
CH1(&CH2&CH
3&CH4)
Definition of the num-
ber of input channels.
Sensor
B&K Vibro sen-
sors; Variable
Sensor type
Sensor Units e.g. g Sensor unit
Sensitivity
e.g. 100 (mV/
Sensor Units)
Sensitivity per sensor
unit.
CCS Power On; Off
Constant Current Sup-
ply. Depends on selec-
tion in Sensor.
Display For-
mat
Spectrum;
Time; Spect-
rum+Time ;
Spect-
rum+Phase;
Spect-
rum+Cross
Phase; Orbit
Analysis which is dis-
played during the mea-
surement.
Spectrum+Cross
Phase and Orbit are
available for precisely
2 input channels.
Units
g; m/s
2
; mm/s ;
m; Envelope
SED; Envelope
BCS
Display unit. Up to two
input channels are
also available for
envelope spectra SED
and BCS with the rele-
vant units ECU and
BCU.
SED Band e.g. 1 to 10 kHz
Only appears if an
envelope spectrum
has been selected
under Units.
Frequency
Type
Hz; CPM;
Orders
The inscription or unit
for the X-axis.

Table of Contents