EasyManua.ls Logo

BRUEL & KJAER VIBROPORT 80 - Tracking - Signal Processing Setup

BRUEL & KJAER VIBROPORT 80
131 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Translation of the Original Operating Instructions
VP-80/VP-80 E
113
9.6.1 Tracking - signal processing setup
Tab. 13 Setup parameters for tracking before calculation
Parameter
Setting para-
meter
Explanation of para-
meter
Channels CH1; CH2; CH3
Channel used for cal-
culation.
Start
Speed(RPM)
e.g. 600 rpm
Definition of data
acquisition speed…
Stop
Speed(RPM)
e.g. 1.500 rpm
Definition of data
acquisition speed…
Spacing
e.g.
rpm
Type of delta or inter-
val of the X-axis.
Speed Inter-
val (RPM)
e.g. 10 Value of speed interval
Time Interval
(s)
e.g. 1 Value of time interval
Display Units e.g. g
Display unit after cal-
culation, which per-
forms an integration
during the calculation if
required.
LF Cutoff On; Off
Filter for filtering low-fre-
quency interference.
Detection rms; pc; ppc
Signal detection or
detection of overall.
Y-axis
Linear; Logarith-
mic
Scaling of Y-axis
Show Overall On; Off
In addition to the dis-
played orders, a total
vibration overall can
be displayed.
Num Traces 1; 2; 3 (4)
Number of orders to be
calculated.
Order #1
(#2,#3,#4)
e.g. 4
Orders which are cal-
culated.

Table of Contents