10
3 Safety in Potentially Explosive Atmospheres
3.1 ATEX certificate and markings
Explosion protection
according to 94/9/EC, only for VP-80 E.
EC-type examination certificate
TRAC10ATEX31265X
Marking
Compliance with standards
EN 60079-0:2009
EN 60079-11:2007
Further explosion-protection approvals for VP-80 E
IECEx TRC 10.0011
Maximum values
• Channel CH1 & CH2
U
0
= 25 V
I
0
= 2.9 mA
P
0
= 100 mW
C
i
= 0
L
i
= 0
• Channel USB DEV / TRIG / PWR
U
0
= 5.5 V
I
0
= 75 mA
P
0
= 275 mW
ATEX II 3G Ex ic IIC T4 Gc Ta= -10°C to +50°C