EasyManua.ls Logo

Bruker AXS Typ BR 058-31 User Manual

Default Icon
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Mounting and
Operating Manual
for
Water Chiller
Typ BR 058-31
ERL 3000 TA
Deckblatt BR 058-31 e.doc/Ausgabe 27-2010
Question and Answer IconNeed help?

Do you have a question about the Bruker AXS Typ BR 058-31 and is the answer not in the manual?

Bruker AXS Typ BR 058-31 Specifications

General IconGeneral
BrandBruker AXS
ModelTyp BR 058-31
CategoryChiller
LanguageEnglish

Summary

User Information

Safety Instructions

General guidance and adherence to safety instructions within the operating manual.

List of Danger Notices

Material-related dangers

Dangers associated with materials used in the system, including cooling agents and oils.

Process-related dangers and process documentation

Dangers arising from the process itself and the importance of process documentation.

Analysis of process dangers

Recommendation for regular analysis of material and process-related dangers.

Designated/Intended Usage

Unpacking and Handling

Transport

Storage

Assembly and Installation

Hydraulic Connection

Guidelines for connecting and laying piping for liquids by qualified personnel.

Electrical Connection

Instructions for electrical connection, including rotational direction check and protection.

Setting Up

Procedures for positioning the cooling equipment at its intended place, ensuring stability.

General Information

Recommendations for transportation, handling, and general operational safety checks.

Application, Function and Description

Description - Refrigeration Unit

Overview of the refrigeration unit's function, components, and operational principles.

Safety Facilities

Description of safety components like high pressure switches and mains isolation devices.

Monitoring Facilities

Explanation of monitoring systems such as low pressure switches and overheating protection.

Putting into Operation and Operating

Safety Checks Before Putting into Operation

Procedures for safety inspections before initial operation and at the customer's location.

Safety Checks During Operation

Obligations for maintaining safety-related inspection documentation during operation.

Preparation for Putting into Operation

Steps for connecting the unit to supplies and filling with cooling medium.

Switching On - Putting into Operation

Instructions for initial start-up, checking connections, and pump operation.

Maintenance

Maintenance for the Operator

Regular checks of cooling medium, screw connections, and air intake by the operator.

Notes on Replacement of Components

Guidelines for using only manufacturer-recommended spare parts and approved replacement procedures.

Warranty Provisions

Taking Out of Operation

Breakdown: What is to be done if ...?

Information about Spare Parts

Details about Disposal and Recycling

Rules for the Owner/Operator

Rules Referring to the Refrigeration Unit

Obligations of the owner/operator regarding trained personnel, operating instructions, and maintenance.

Planning for Emergencies and Assignment

Recommendation to integrate the equipment into emergency measures and control plans.

Operational Regulations and Safety Practices

Importance of including operational regulations into local rules and understanding the operational language.

Appendices

Technical Data Sheet

Annex Dimensions

Annex System Scheme

Annex Pump Performance Characteristic

Annex Electrical Data

Troubleshooting Table

Compact Controller with Program Function

Brief Description of the Controller

Overview of the controller's capabilities, display, and basic operation.

Controller Block Structure

Diagram illustrating the controller's input/output configurations and option boards.

Controller Approvals and Conformity Marks

Listing of certifications and marks of conformity for the controller series.

Self-Optimization Function

Explanation of the self-optimization feature for matching the controller to the control loop.

Timers and Setup Program

Functionality of timers and the PC-based setup program for configuration.

Program Function Details

Implementation of setpoint profiles with program segments and time settings.

Parameter Level Settings

Description of controller parameters and their factory settings, including two parameter sets.

Technical Data

Thermocouple Input Specifications

Technical details for thermocouple inputs, including measuring ranges and accuracy.

Resistance Thermometer Input

Specifications for resistance thermometer inputs, including sensor types and accuracy.

Standard Signal Inputs

Details on inputs for standard voltage and current signals, including accuracy.

Logic Input Specifications

Information on logic inputs, specifically for floating contacts.

Measuring Circuit Monitoring

Monitoring capabilities for sensor faults like overrange, underrange, short-circuit, or break.

Output Specifications

Details on available output types: relays, solid-state relays, voltage, and current outputs.

Electrical Data

Supply voltage, electrical safety, power consumption, and data backup details.

Housing and Environmental Data

Specifications for the controller housing, mounting, and environmental conditions.

Interface Specifications

Details on Modbus and PROFIBUS-DP interfaces for communication and data transmission.

Sensors for Air and Water/Oil Operation

Approved sensors for air and water/oil operation, including types, ranges, and process connections.

Dimensions

Close Mounting Spacing

Minimum spacing requirements for panel cut-outs for different controller models.

Order Details

Basic Controller Types and Options

Overview of controller models, extensions, supply voltages, extra codes, and approvals.

Water Quality Requirements

EC Declaration of Conformity

Spare Parts Recommendation