P2233
FIG. 5 BREW SELECTOR SWITCH TERMINALS
BREW SELECTOR SWITCH (cont.)
SERVICE (cont.)
Removal and Replacement:
1. Disconnect the connector on the selector switch
harness from the DBC controller.
2. Disconnect wires from the selector switch, inter-
face socket and dispense valve.
3. Loosen the set screw on the switch knob.
4. Remove the 9/16" nut and washer holding the
switch to the hood.
5. Remove the switch.
6. Install the new switch. The positioning tab must be
in the hole in the hood for proper switch and knob
alignment.
7. Install the knob so that the arrow points to the 1-
1/2 or 1-3/4 gallon position when the switch is
turned to the full right position.
8. Reattach the connector to the DBC controller.
9. Refer to Fig. 5 when reconnecting the wires.
32248 100500