●
The vehicle controller can memorize
the SOC setting value set last time.
CAUTION
●
When the vehicle runs stably at
a certain speed after the engine
startup, a part of the torque
output by the engine drives the
generator to generate electricity
and charge the power battery.
●
If the dierence between the
current power and the SOC set
value is large, it may take a long
time to reach the set value.
●
The SOC setting range may
change depending on the vehicle
state or the environment that the
vehicle is in.
SOC Setting
●
The State of Charge(SOC)means the
state that the user expects the vehicle
to reach during driving. Pull down
the status bar on the top of the
infotainment or go to (infotainment
system) → New Energy → Energy
Manager for SOC settings.
●
Set SOC to the target remaining power
●
If it is convenient to charge the
vehicle at the destination, it is
recommended to lower the SOC set
value to make full use of the stored
electric energy to drive the vehicle
and save fuel consumption.
●
If it is inconvenient to charge the
vehicle at the destination, it is
recommended to increase the set
value to maintain the battery SOC
level of the vehicle and improve the
driving experience.
●
In order to ensure the proper driving
and riding experience, the vehicle
automatically adjusts the SOC set
value according to the altitude and
ambient temperature.
●
Intelligent /forced power protection
function setting
●
Intelligent SOC hold: give priority
to fuel economy and consider the
demand for SOC hold.
●
Compulsory SOC hold: give priority
to SOC hold, and keep the SOC level
as close as possible to the set value.
Energy Regeneration Intensity Settings
Go to the
(infotainment system)
→ New Energy → Energy Manager to
choose Standard or High mode of Energy
feedback intensity according to driving
habits.
●
If the mode is not set by the user,
the factory default setting is always
maintained.
●
The set value is memorized and
becomes the default value after each
power-on.
In-Situ Power Generation Function
When the SOC is lower than a certain
value during parking, the engine drives
the alternator to charge the high-voltage
battery. During power generation, it is
normal that the engine speed is dierent
from the normal idle speed. The in-situ
power generation is disabled until the
SOC is equal to or higher than a certain
value.
REMINDER
●
During the in-situ power
generation, the instrument
cluster may show a slightly
lower generated power due to
the consumption of electrical
appliances.
105
04
USING AND DRIVING