C.A.R.E 2000-ADS
Maintaining Your C.A.R.E. 2000
CLEANING AND CHANGING FILTERS
THE HEPA & CARBON DRUM FILTER
FOR YOUR INFORMATION - HEPA LIFE RATING
The HEPA filter MAY last up to 5 years in some areas, The carbon filter MAY last up to 2 years.
the longevity of the HEPA or the carbon filter depends on the amount of use and the amount of
contaminants in the room air where the filter is being used. After changing the "Pre-filter" if the
red light stays on, you should change the inner HEPA drum. As the carbon media comes to the
end of its life, chemically and environmentally sensitive (MCS) people may detect contaminants
at lower levels and will have to change the filter sooner.
THE FREQUENCY GUIDELINES FOR THE CHANGE OF FILTERS
The frequency of HEPA and car-
bon filter changes will vary de-
pending the amount of contami-
nants in your indoor environment.
NOTE:
The chart to the right shows only estimates
of the life of the filters. Frequency of filter
changes may be shorter.
IF THE RED INDICATOR LIGHT REMAINS ON.
If cleaning or changing the pre-filter does not shut off the red indicator light, this signal means that
the inner HEPA filter needs to be changed. Call your distributor and order a HEPA replacement
filter.
HOW TO CHANGE THE HEPA & CARBON FILTER
1. UNPLUG THE UNIT BEFORE
SERVICING.
2. Follow steps 1 to 4 in the HOW TO
CLEAN YOUR PRE-FILTER section
(page 4)
3. Remove inner HEPA drum FIG.6
4. Place the new HEPA drum inside of
the old carbon filter; or place old HEPA
drum into new carbon filter.
5. Place complete HEPA + carbon filter
with pre-filter wrapped around filter,
into inner chamber with the open end of
HEPA facing towards the top of the
CARE unit.
6. Replace rear access panel and
replace (2) bottom screws.
SENILEDIUGYCNEUQERF
GNINAELCRETLIF-ERP
4-2OTPU
SHTNOM
RETLIFTSOP&ERP
EGNAHC
RAEY2
EGNAHCRETLIFAPEHSRAEY5OTPU
RETLIFNOBRACSRAEY2OTPU
EGNAHCSPMALVURAEY1
5
IMPORTANT:
DO NOT STAND UNIT UPRIGHT UNLESS
HEPA/CARBON FILTER IS IN PLACE.
FIG.6
INNER HEPA DRUM
OUTER CARBON
FILTER