PH-SERIES
4
FIRE OR EXPLOSION HAZARD
The PH-40, 50, 75, 80, 100, and 125 heaters must not be connected to a chimney flue serving a separate solid-
fuel burning appliance. These models, in a space heating application, must only be installed with the venting
that they are certified for. Refer to the installation instructions for installation details. If you are installing a
PH-40, 50, 75, 80, 100, and 125 unit indoors it will need to be vented either with a sidewall vent kit, (use pin
#800208 sidewall vent kit) or via a certified “B” vent system through the roof. For side wall applications, make
sure vent cap is past eave (See venting section for both types of installation) PH-40HO, PH-75HO, PH-80HO,
PH-100HO and PH-125HO units are for outdoor applications only.
Make sure units are operating as quiet and efficient a possible before leaving the job site and instruct owner/s
on the safe operation of the heater as well as safety and hazardous issues as they relate to the heater, it’s
installation, operation and this manual.
Leave this manual with the consumer and instruct them to retain the manual for future reference.
WARNING:
California Proposition 65
If not installed, operated and maintained in accordance with manufacturer's instructions. This product could
expose you to substances in the fuel or from combustion which can cause death or series illness and which
are known to the State of California to cause cancer, birth defects or reproductive harm.
HEATER OPERATION NOTE: PH-40, 50, 75, 80, 100, and 125 Patio Heaters will have a higher heat output at
the burner end as compared to the exhaust end.
SPACE HEATING: As a general rule, it is suggested to locate the burner end toward the highest heat-loss area
(doors) of the space being heated. If you have any concerns or questions concerning orientation or layout of
the heater in your application, contact factory for assistance.
SPOT HEATING: On PH-40, 50, 75, 80, 100, and 125 heaters with a straight line configuration, there will be a
noticeable and more pronounced perception of greater heat output from the burner end of the heater as
compared to the exhaust end. As a general rule, it Is suggested for spot heating applications, to use the PH-
40HO, PH-75HO, PH-80HO, PH-100HO or PH-125HO models or a u-tube configuration to provide a more even
source of heat; or two units, side by side with the burner heads at opposite ends to promote even heating. If
you have any concerns or questions concerning orientation or layout of the heater in your application,
contact factory for assistance.
NOTE: A small amount of condensation may occur from the heater when it starts the heating cycle. The
condensation will stop once the heater warms up. On models PH-40, 50, 75, 80, 100, and 125 and if using a
venting system, make sure venting is sealed and installed according to section title VENTING