TH52D2-R_ii_161005 Pg 1
StyleTherm
TH52D2- R
½” Thermostatic Valve w/ Dual Non-Shared & Single Control Outlets
Installation Instructions
IMPORTANT: Read all instructions prior to installation and provide copy of instructions to consumer.
WARNING: This valve is factory set to deliver water at 100°F; however, it is the installers responsibility to verify correct temperature
setting to prevent risk on scalding or other severe injury prior to consumer use. The installer is responsible for adjusting maximum
temperature setting according to Thermostatic Rough and Thermostatic Trim Installation Instructions.
Operating Specifications:
Recommended Supply Pressure: 20 to 70 psi
*†
Recommended Hot Water Supply Temperature: 120 to 140°F
Nominal Flow Rate @ 60 psi (non-shared port): 7.2 gpm
Nominal Flow Rate @ 60 psi (lower port): 10.5 gpm
* Operating pressures between hot and cold supplies should vary no more than 30 psi.
If water pressure exceeds 70 psi, install a Pressure-Reducing Valve (RPV).
Follow all applicable local plumbing codes when setting the temperature on the water heater.
CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED
BY A LICENSED PROFESSIONAL
Body
Dual Non-Shared
Volume Control
Thread
Protector
Thread
Protector
Mudguard
Mudguard
Screw
Mudguard
Washer
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
Flow Rate (GPM) at 60 psi
Volume Control Lever Rotation
(0=full open RT, 90=closed & 180=full open LT)
Dual non-shared volume control (upper port)
Single Volume
Control
Question and Answer IconNeed help?

Do you have a question about the California Faucets StyleTherm TH52D2-R and is the answer not in the manual?

California Faucets StyleTherm TH52D2-R Specifications

General IconGeneral
BrandCalifornia Faucets
ModelStyleTherm TH52D2-R
CategoryPlumbing Product
LanguageEnglish

Summary

Installing Valve to Frame

Water Connections

Finished Wall Installation

Maintenance Procedures

Thermostatic Cartridge Service

Instructions for removing, cleaning, and reinstalling the thermostatic cartridge, including lubrication advice.

Check Valve Service

Steps for removing, cleaning, and reinstalling check valves, including lubrication and tightening specifications.

Rough-In Dimensions