Operating instructions
EVS17/07-DS/IU und EVS17/12-DS/IU
Refrigerator
Changeover switch to position K ==> compressor operation
The refrigerator is supplied via the permanent positive when the main switch is
turned on at the control panel.
Power supply Alternating voltage 230 V / 50 Hz, single phase
Range ca. 215 V - 245 V.
Output current Charging current max. 7 A, arithmetic average, electro-
EVS 17/07-DS/IU: nically regulated according to the charging characteristic
curve IUoU.
Output current Charging current max. 12 A, arithmetic average, electro-
nically regulated according to the charging characteristic
curve IUoU.
Output voltage: 12 V DC
Charging process: automatic
Autom. switching: ON when battery voltage reached 13,5 V
(Main charging OFF when battery voltage reached 14,4V
process)
Autom. switching: six hours constant at 14,4 V
(Timer)
Autom. switching: Holding charge constant at 13,8 V
(Holding charge)
Application: Parallel operation, buffer operation, general charging
operation
Temperature: Ambient temperature of -25° C bis +25° C. During
operation, the housing may heat up to ca. 70° C.
Cooling: by convection
Implementation: According to Association of German Electrotechnical
Engineers regulations and the provisions of the Instrument
Safety Act.
Test labelling: