high ambient temperature, the charging current is automatically reduced in
steps.
Fig. 1
12 volt user circuit fuses
The 12 volt user circuit fuses are easily accessible on the
upper side of the housing. There are six flat plug-
in fuses
that are easily exchanged with the aid of the fuse
extraction pliers supplied.
Fridge – 15 A fuse
Permanent current for heating and immediate light 7.5 A
Waste water tank heater – 5 A fuse
Water pump – 5 A fuse
User circuit 2 – 10 A fuse
User circuit 1 – 10 A fuse
Fig. 2
Circuit breaker 230 volt
The circuit breaker for the 230 volt mains protection is
also easily accessible on the
upper side of the housing.
Each according to implementation with or without 30
mA
differential circuit breaker.
Supply battery charging procedure (battery II)
The power supply has electronic protection against polarity inversion. The