Cable lengths and cross-sections
Only use the specified cross-sections!
12-pole plug connector
Battery I positive pole
Charging cable red
For length of up to 3 m, cable cross-section 10 mm².
For length of up to 6 m, cable cross-section 10 mm².
Length over 6 m, cable cross section 16 mm².
Battery II positive pole
Charging / supply cable
red
For length of up to 6 m, cable cross-section 10 mm².
Battery II negative pole
Charging / supply cable
blue
For length of up to 6 m, cable cross-section 10 mm².
Connection
Disconnect the power cables from the battery
and from the mains before connecting /
disconnecting any cables!
Connection to the control panel
12-pole flat plug
Plug the 12-pole flat cable into your control panel. The assignation of the
contacts is according to the following list:
Fig. 6: 12-pole connector

Terminal 1 Negative connection

Terminal 2 + Test connection for battery II
 Terminal 3 + Test connection for battery I
 Terminal 4 Control connection for user relay