p. 24 - Manual FA01294-EN - 12/2018 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Opening slow-down point
Sets the opening slow down start point (percentage of the total travel).
This function appears only is the [Encoder] function is active.
F37 Opening slow-down point From 10% to 60% (25% Default)
Closing slow-down point
Sets the closing slow down start point (percentage of the total travel).
This function appears only is the [Encoder] function is active.
F38 Closing slow-down point From 10% to 60% (25% Default)
RSE
Configures the function to be performed by the board connected to the RSE connector.
F49 RSE 0 =Deactivated (Default)
1 = Paired
3 = CRP
Saving data
Save user data, timings and configurations to the memory device (memory roll or USB key).
The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.
F50 Saving data 0 =Deactivated (Default)
1 = Activated
Data reading
Loads user data, timings and configurations from the memory device (memory roll or USB key).
The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.
F51 Data reading 0 =Deactivated (Default)
1 = Activated
Transferring MASTER-SLAVE parameters
It enables to share the parameters programmed on the Master gate with the Slave gate.
This function appears only is the [RSE] function is active in combination.
F52 Transferring MASTER-SLAVE
parameters
OFF (Default)
ON
Opening direction
It sets the gate opening direction.
F54 Opening direction 0 = To the left (Default)
1 = To the right
CRP address
Assigns a unique identification code (CRP address) to the electronic board. The function is necessary if there are more operators connected by CRP.
F56 CRP address from 1 to 255