0.2 03/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Terminals for powering the following accessories:
- 24V a.c. (normally alternated power);
- 24V a.c. (continuous power) when the emergency batteries are in operation;
Overall power allowed: 40W
Power supply
Power supply 230V (a.c.) 50/60 Hz
Cable lug with bolt and washer for
connecting to earth
Stop button (N.C. socket) - Bar stop button. Excludes automatic closing. For motion to resume, press the com-
mand button or the remote control button.
If not used, set Dips 9 to ON.
Command button (N.O. contact) - Bar opening or closing button.
By pressing on the button, the bar opens or inverts its movement
depending on the selection made on Dipswitch 2.
Check setting of the Jumper (n. 14, page 15), as per fi gure.
Opening button (N.O. contact) - Bar opening command.
Command devices
Closing button (N.O. contact) - Bar closing command. Obliga-
tory in the event of “maintained action” function.
Set jumper according to fi gure.
(N.C. )Contact for “immediate closing”
Automatic bar closing after an obstacle comes within the range of the
safety devices.
If not used, set Dip 8 to ON.
DIR photocells