L
N
+ E
-
EbA EbA EbI EbI
10
S2
S1 2 EM 4 3 2 1 11
1
5
4
6
3
2
2
7
8
9
Pag.
21
21 -
Manual code
:
119G3055
119 G30 55 ver.
1.0
1.0 10/2009
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
N.B. If the cable length differs to that shown in the table, determine cable section based on the actual power draw by the connected
devices and according to what is prescribed by law CEI EN 60304-1.
For sequential connections on the same line, length-measurements by the table must be converted on the basis of draw and actual
distances. To connect any products not mentioned in this manual, see documentation provided with said products.
Connection Cable type
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
230V power supply to control panel
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Power supply to accessories 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Control and safety devices 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
8 Control panel
Transformer1.
Transformer connection terminals2.
1.6A accessories Fuse3.
Endpoint connection terminal4.
1.6° line fuse 1.6° line fuse5.
230V A.C. control board power terminals6.
Terminals for connecting accessories and com-7.
mand and control systems
electro-block connection terminal board8.
Stop/Go lights connection terminal board. 9.
8.2 Main components
The control panel is powered by 230V A.C. on terminals L-N,
with max frequency of 50/60Hz.
The command and control devices and accessories are 24V.
All connections are quick-fuse protected, see table.
The defi nable command and control functionalities are:
- clock-wise activation;
- counter clock-wise activation;
- override release command;
- emergency command.
WARNING: before doing any work inside the equipment, cut the
power mains.
8.1 General description
7.1 Cable type and section
FUSE TABLE
To protect: Fuse rating:
Control board (line) 1,6A-F
Accessories 1,6A-F
TECHNICAL DATA
Power voltage 230V - 50/60 Hz
Power draw 223 mA
Max allowed power for 24V 35 W
Class II Circuit insulation II
24V current provided by the board is of the SELV type
Intelligent Security & Fire Ltd.