Panic button / (N.C. contact)
Activating the contact triggers total block of the turnstile.
Exit Button or Transponder / (N.O. contact)
- Activating the turnstile to exit. With a non permanent
contact after 10” if no other command is given the turnstile
again blocks automatically. With permanently closed con-
tacts after 10” it is continuously activated.
Entrance Button or Transponder / (N.O. contact)
- Activating the turnstile to enter. With a non permanent
contact after 10” if no other command is given the turnstile
again blocks automatically. With permanently closed con-
tacts after 10” it is continuously activated
Emergency button / ( N.C. contact)
Activating the contact frees the turnstile to turn in any direc-
tion and if maintained inhibits all other commands.
9.3 Connection optional devices to the control panel
24V A.C. / 500 mA power supply to accessories
Once the power is connected wait 10 seconds before initiating any turnstile action