19
ON
OFF
1. Momentarily pulse terminals 2 & 3 with a
piece of wire trailing from terminal 2 and
momentarily touching terminal 3.
The gates should start to open. If they start
to close turn the power off to the control
panel and change around either U-V (motor
1) or X-Y (motor 2) to change the motor
direcrion.
2. Once you have proven the motor direction
use terminals 2 & 7 to open and close the
gates with a trailing wire once again into
terminal 2, momentarily touching terminal 7.
5. Select dipswitches 1 & 2 OFF for
commissioning.
6. Ensure hard wire link is fitted between
terminals 1 & 2 and 2 & C1.
L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1
L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1