29
5.4 - Control Panel Adjustments
Trimmer T.L - Adjustment of operating time from a minimum of 0 seconds to a maximum of 120
seconds N.B. it is advised to let the motors run on for between 6 and 8 seconds after the last gate has
fully close.
Trimmer T.C.A - Adjustment of automatic closing time from a minimum of 1 to a maximum of 120
seconds.
Trimmer T.R.2.M - Partial opening time adjustment and delay in closing of the second motor leaf
delay from a minimum of 0 seconds to a maximum of 20 seconds.