FUNCTIONS AVAILABLE
(see pages 22 through 26)
->
Automatic closing.
The automatic closing
timer is automatically activated at the end of
the opening cycle.
The preset, adjustable automatic closing
time is automatically interrupted by the activa-
tion of any safety system, and is deactivated
after a STOP command or in case of power
failure;
->
Photocells safety test.
The control unit will
now check the safety system every time an
opening or closing command is given (4 dip
switch selector)
.
->
Obstacle detection.
When the motor is
stopped (gate is closed, open or half-open after
an emergency stop command), the transmitter
and the control pushbutton will be deactivated
if an obstacle is detected by one of the safety
devices (for example, the photocells);
->
Hammer movement.
The door wings momen-
tarily press against the closure stops when the
open command is given, which facilitates release
of the electric lock;
->
Cycle lamp
to light the passage area: it
remains on from the moment the doors begin
to open until they are fully closed (including
the automatic closing time). If automatic clos-
ing is not activated, the lamp remains on only
during movement.
->
"Maintained action" function:
Gate operates
only when the pushbutton is held down (the radio
re mo te control system is deactivated);
->
Flashing light
activated before opening and
closing cycle begins;
->
Type of command:
• «
open-stop-close-stop
» for pushbutton
and radio transmitter;
• «
open-close-reverse
» for pushbutton
and radio transmitter;
• «
open only
» for radio transmitter.
ADJUSTMENTS
-> Trimmer FINE ADJ/AMP SENS= Fine adjust-
ment of amperometric sensitivity during motor
operation: min/max;
-> Trimmer AMP SENS = Adjustment of amper-
ometric sensitivity during operating: min/max;
-> Trimmer SLOWDOWN/AMP SENS = Ad-
justment of amperometric sensitivity during
slowdown: min/max;
-> Trimmer ACT = Adjustment of automatic
closing time: 2" to 120";
-> Trimmer DELAY 2M = Delay on closing cycle
motor 2: 1" to 15";
-> Trimmer OP TIME =
Adjusting of the stop
zone (open/closed position, see page 28)
;
-> Faston connectors on the circuit card are
used to
select normal operating and slowdown
speeds
(see page 34)
;
Caution! Shut off the mains
power and disconnect the batteries be-
fore servicing the inside of the unit.