Programming the end-stop in the closing and opening phase
- Position dip-switch n°1 to ON (the programming signal led fl ashes).
Push and keep pressed the AP/CH switch until the door closes...
...then press the ENC/RADIO button until the signalling led stays on for some seconds and then resumes blinking (the program-
ming operation is satisfactorily complete).
Programming the end-stop in the closing phase
- Push and keep pressed the OPEN button until the door is fully open...
...then press the ENC/RADIO button until the signalling led stays on (the programming operations is satisfactorily complete).
Finally, set dip switch n°1 back to OFF.
Programming the end-stop in the opening phase
TEST
Use the AP/CH button to command both an opening and a closing to verify whether the programmino was successful.