The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
Pag.
9
- Manual code:
319
319
LR0
LR0
5
ver.
1.
1.
1
01/2008 © CAME cancelli automatici s.p.a.
ENGLISH
Electrical connections
Antenna connection
Encoder connection
10-E 2-7
M-N
1-2
10-11
2-C1
+ E -
L-N
230V a.c. – 50/60 Hz Power supply Stop button (N.C. contact)
Opening and closing devices (N.O. contact). Flashing light (contact capacity: 24V – 25W max.)
24V d.c. Gearmotor
N.C. Contact for “reopening during closing”
Teminal board for accessories’ power supply:
- at 24V a.c. normally;
- at 24V d.c. when the emergency batteries are in operation;
Maximum total power allowed: 40W.