Saving the trimmer value
Use the trimmers to set the automatic closing time (A.C.T.), the opening and closing latching points, the
second motor's closing-delay speed, the slow-down speed (SDS) and the sensitivity (SENS.).
To save the values:
select the DIP-switches as shown and press the PROG button on the control board. The PRG LED stays lit
and the buzzer sounds once.
Services test
By default, the feature is disabled.
To enable it:
Select the DIP-switches as shown and press the PROG button on the control board. The LED stays lit and
the buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Button-activated maintained action
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays lit and the
buzzer sounds once.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
⚠
The gate opens and closes when the button is kept pressed.
Opening button connected on 2-3P (contact NO) and closing button connected on 2-7 (contact NO)
All other control devices, even radio-based ones, are excluded.
Partially open
Door opening approx. 36°, cannot be changed.
Select the DIP-switches as shown and press the PROG button for one second. The PRG LED flashes.
Within 20 seconds, enter a code from the keypad selector or press any button on the transmitter
that you want to save.
Once the saving is finished the PROG LED turns on and the buzzer sounds off once.
If the transmitter has been previously saved or the maximum number of registered users is exceeded
the LED flashes quickly and the buzzer sounds off seven times.
SERVICING UP TO 25 USERS
Open only
Select the DIP switches as shown and press the PROG button for one second. The PRG LED flashes.
Within 20 seconds, enter a code form the keypad selector or press any button on the transmitter
that you want to save.
Once the saving is finished the PROG LED stays on and the buzzer sounds off once.
If the transmitter has been previously saved or the maximum number of registered users is exceeded
the LED flashes quickly and the buzzer sounds off seven times.
OPEN-CLOSE-INVERT
Select the DIP switches as shown and press the PROG button for one second. The PRG LED flashes.
Within 20 seconds, enter a code form the keypad selector or press any button on the transmitter
that you want to save.
Once the saving is finished the PROG LED stays on and the buzzer sounds off once.
If the code has been previously saved or the maximum number of registered users exceeded, the
LED flashes quickly and the buzzer sounds off seven times.
OPEN-STOP-CLOSE-STOP
Select the DIP switches as shown and press the PROG button for one second. The PRG LED flashes.
Within 20 seconds, enter a code from the keypad selector or press any button on the transmitter
that you want to save.
Once the saving is finished the PROG LED stays on and the buzzer sounds off once.
If the code has been previously saved or the maximum number of registered users exceeded, the
LED flashes quickly and the buzzer sounds off seven times.
Deleting all users
Select the Dip-switches as shown and press the PROG button for five seconds.
Once deletion is complete, the PRG LED stays lit and buzzer sounds off for one second.
Resetting parameters
Select the Dip-switches as shown and press the PROG button for five seconds.
Once deletion is complete, the PRG LED stays lit and buzzer sounds off for one second.
This function does not delete any users.