Page 15 - Manual FA02007-IT - 11/2023 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions
ALERTS POSSIBLE CAUSES FIXES
THE PROG LED flashes
and the buzzer sounds
every 5 s
• The control board does not work • Call for assistance
The PROG LED flashes
and the buzzer sounds off
seven time
• Self-learning error • Check that the gearmotor and encoder
are properly connected
• Encoder error • Call for assistance
• Services test error • Check that the photocells are connected
and working properly
• Operating time error • Check that the gearmotors and the
operating-time setting are in order
• Maximum number of
obstructions consecutively
detected (max 5)
• Remove obstruction
• Error during the resetting of
parameters or deleting of users
• The PROG key must be pressed for over
5 seconds
• User already saved or maximum
number of registered users
exceeded
• Check whether the user is, in fact, saved
TROUBLESHOOTING
DISMANTLING AND DISPOSAL
Decommissioning and dismantling - always check the current applicable law before continuing. The packaging
materials (cardboard, plastic, and so on) should be disposed of as solid household waste, and simply separated
from other waste for recycling.
Whereas other components (control boards, batteries, transmitters, and so on) may contain hazardous
pollutants. These must therefore be disposed of by authorized, certified professional services.
DISPOSE OF RESPONSIBLY!
FINAL OPERATIONS
Fastening the cover
Once finished with the electrical connections and powering
up, fit the cover and secure it using the supplied screws.