EasyManua.ls Logo

CAME ZL65 - CX input; CY input; Safety devices test; Hold-to-run

CAME ZL65
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 17 - Manual FA01359-EN - 03/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
CX input
Associate a function with the CX input.
The parameter [C3] appears only if the [Automatic closing] function is active
F2 CX input OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic
close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive
edges)
C8 = Reclose while opening (sensitive
edges)
CY input
Associate a function with the CY input.
The parameter [C3] appears only if the [Automatic closing] function is active
F3 CY input OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic
close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive
edges)
C8 = Reclose while opening (sensitive
edges)
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
The safety devices test function is always active for wireless safety devices.
F5 Safety devices test OFF (Default)
1 = CX
2 = CY
4 = CX+CY
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
F6 Hold-to-run OFF (Default)
ON

Related product manuals