Soft start
Set a slowdown of a few seconds after each opening and closing command.
F12 Soft start OFF (Default)
ON
Closing thrust
When the leaves reach the closing limit-switch, the operator performs a closing thrust for a few seconds.
F13 Closing thrust OFF (Default)
1 = Minimum thrust
2 = Medium thrust
3 = Maximum thrust
Sensor type
Set the type of control device.
F14 Sensor type 0 = Transponder selector or magnetic
card reader
1 = Keypad selector (default)
Thrust
Before every opening or closing manoeuvre, the leaves thrust inwards to release the electric lock.
F16 Thrust OFF (Default)
ON
Additional light
Choose the operating mode of the lighting device connected to output 10-E.
F18 Additional light 0 =Flashing beacon (Default)
1 = Cycle light
The lamp stays on during the
manoeuvre.
Parameter [1] appears only if an
automatic closing time is set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached or once the photocells
have caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a
complete stop, or during a power outage.
F19 Automatic close OFF (Default)
From 1 to 180 seconds