EasyManua.ls Logo

CAME ZL65 - Automatic closing after either partial or pedestrian opening; Pre-flashing time; Operating time; M1 opening delay time

CAME ZL65
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 20 - Manual FA01359-EN - 03/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Automatic closing after either partial or pedestrian opening.
Set the time before automatic closure is activated, after a partial opening command has been performed or after the
photocells have caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a
complete stop, or during a power outage.
F20 Automatic closing after either
partial or pedestrian opening.
OFF (Default)
From 1 to 180 seconds
Pre-fl ashing time
Set the time for which the beacon is activated before each manoeuvre.
F21 Pre-fl ashing time OFF (Default)
1 to 10 seconds
Operating time
Set the gearmotor working time during opening and closing.
F22 Operating time 5 to 180 seconds (Default 120)
M1 opening delay time
It adjusts the delay with which the fi rst leaf must start the opening manoeuvre with respect to the second leaf.
F23 M1 opening delay time 0 to 10 seconds (Default 2)
M2 closing delay time
It adjusts the delay with which the second leaf must start the closing manoeuvre with respect to the fi rst leaf.
F24 M2 closing delay time 0 to 25 seconds (Default 5)
Thrust time
Adjust the gearmotor closing thrust time after an opening or closing command.
F26 Thrust time 1 to 2 seconds (Default 1)
Electric lock time
Adjust the electric lock release time after an opening or closing command.
F27 Electric lock time 1 to 4 seconds (Default 1)
Gate travel speed
Set the travel speed (percentage of maximum speed).
F28 Gate travel speed 40% to 100% (Default 100%)
Slowdown speed
Set the slowdown speed (percentage of maximum speed).
F30 Slowdown speed 15% to 60% (Default 50%)