Calibration speed
Set the speed during travel self-learning (percentage of maximum speed).
F33 Calibration speed 20% to 60% (Default 50%)
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel (percent).
F34 Travel sensitivity 10% to 100% (Default 100%)
10% = minimum thrust and high
obstruction sensitivity
100% = maximum thrust and low
obstruction sensitivity
Slowdown sensitivity
Adjust the obstruction detection sensitivity during slowdown (percent).
F35 Slowdown sensitivity 10% to 100% (Default 100%)
10% = minimum thrust and high
obstruction sensitivity
100% = maximum thrust and low
obstruction sensitivity
Adjusting the partial opening
In single-leaf gates, it determines the leaf partial opening percentage with respect to the total travel.
In two-leaf gates, it determines the partial opening percentage of the leaf that moves fi rst with respect to the total travel.
F36 Adjusting the partial opening 10% to 80% (Default 40%)
Opening slowdown point for M1
Set the opening slowdown starting point for M1 (percentage of the total travel).
F37 Opening slowdown point for M1 1% to 60% (Default 25%)
Closing slowdown point for M1
Set the closing slowdown starting point for M1 (percentage of the total travel).
F38 Closing slowdown point for M1 1% to 60% (Default 25%)
Opening approach point for M1
Set the opening approach starting point for M1 (percentage of the total travel).
F39 Opening approach point 1% to 10% (Default 10%)
Closing approach point for M1
Set the closing approach starting point for M1 (percentage of the total travel).
F40 Closing approach point 1% to 10% (Default 10%)