Motor test
Check the gate leaves open in the right direction.
With the function active, in single-leaf gates, the > button opens the gate with the gearmotor connected to M2-N2;
With the function active, in two-leaf gates, the > button opens the gate with the gearmotor connected to M2-N2; the < button
opens the gate with the gearmotor connected to M1-N1.
If the leaf does not move in the correct direction, invert the motor phases.
A2 Motor test OFF (Default)
ON
Travel calibration
Start the travel self-learning.
This function appears only if the [Encoder] function is active.
A3 Travel calibration OFF (Default)
ON
Parameter reset
Restores the factory settings, including the travel calibration settings.
A4 Parameter reset OFF (Default)
ON
Manoeuvre counter
View the number of operator manoeuvres.
001 = 100 manoeuvres / 010 = 1000 manoeuvres /100 = 10000 manoeuvres / 999 = 99900 manoeuvres / CSt =
maintenance job
A5 Manoeuvre counter
FW version
Display the fi rmware version number.
H1 FW version