Page 27 - Manual FA01359-EN - 03/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
ERROR AND WARNING MESSAGES
E1 The travel calibration was interrupted to activate the STOP button.
E2 Adjustment error
E3 Encoder failure error
E4 Service test failure error
E7 Operating time error
E9 Obstacle detected during closing
E10 Obstacle detected during opening
E11 Maximum number of obstacles
E14 Serial communication error
E15 Incompatible remote control
E17 Wireless system communication error
E18 Wireless system not confi gured error
C0 Wired contact 1-2 (NC) is open
C1, C2, C3, C4 The wired photocell contacts (NC) are open.
C7, C8 The wired sensitive-edge contacts (NC) are open.
P0 The wireless radio stop contact (NC) is open.
P1, P2, P3, P4 The wireless radio photocell contacts (NC) are open.
P7, P8 The wireless radio sensitive-edge contacts (NC) are open.
--- Control board has no travel auto-learning