i4
>...>
>...>
>...>
P. 17 - Manual code: 319V21EN Vers. 3 04/2017 © CAME cancelli automatici S.p.A. - The data and information in this manual are subject to change at any time without prior notice required by Came Cancelli Automatici S.p.A.
ENGLISH
F 25 ( Courtesy light time) : supplementary light connected on (10-E), stays on while gate is opening and closing.
The time can be set to between 60” and 180”.
60 = 60 seconds (default setting); 61 = 61 seconds ..................; 180 = 180 seconds.
F 26 (Ram head blow) : thrust time of the gearmotor when in final closing and opening stage after each command.
The time may be set to between 1” and 2”.
Note: this function only appears for the Myto, Frog-J, Stylo-RME and Amico gearmotors.
1 = 1 second (default setting); 2 = 2 seconds.
F 27 (lock time) : action time for releasing the electrolock with each opening or closing command (see F 17).
The time can be set to between 1” and 4”.
Note: this function only appears for the Myto, Frog-J, Stylo-RME and Amico gearmotors.
1 = 1 second (default setting); ................... 4 = 4 seconds.
F 28 (M1 motor speed) : setting the speed of operation of the M1 motor calculated as a percentage:
40 = 40% of the motor speed(minimum); .................. 100 = 100% of the motor speed (maximum and default setting).
F 29 (M2 motor speed) : setting the speed of operation of the M2 motor calculated as a percentage:
40 = 40% of the motor speed(minimum); .................. 100 = 100% of the motor speed (maximum and default setting).
F 30 (Slow-down speed of M1 motor) : setting the speed of the M1 motor during slow downs, calculated as a percentage.
20 = 20% motor slow-down speed (minimum); .................. 50 = 50% motor slow-down speed (default setting);
................. 60 = 60% motor slow-down speed (maximum).