Page 38 - Manual FA01894-EN - 09/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
BUS <n> key selector
Associate a function with the input BUS <n> key selector. Di erent functions can be set according to the key turning direction.
<n> is between 1 and 7 and corresponds to the address set on the key selector dip switch
The function only appears if there is a BUS key selector connected.
Confi guration>
BUS Devices
BUS 1 key selector
BUS 2 key selector
BUS 3 key selector
BUS 4 key selector
BUS 5 key selector
BUS 6 key selector
BUS 7 key selector
Key to the right
Key to the left
Choose the command to associate with the key movement.
Open
Close
Partial opening
Stop
B1-B2 output
BUS 1 module relay - Activate output 2 (relay output) on
BUS 1 I/O module
BUS 2 module relay - Activate output 2 (relay output) on
BUS 2 I/O module
Step-by-step - The fi rst command is to open and the
second to close.
Sequential - The fi rst command is to open, the second to
STOP, the third to close and the fourth to STOP.
I/O module <n> - Inputs
Associate a function to the I/O module <n> inputs.
<n> is between 1 and 2 and corresponds to the address set on the module dip switch.
The function only appears if there is a BUS I/O module connected.
Confi guration>
BUS Devices>
I/O module 1
I/O module 2
input I1
input I2
Deactivated (Default)
Stop = Stop the gate and exclude automatic closing. Use a
control device to resume movement.
If it is activated, the input is used as a normally
closed contact.
r7 = Reopen while closing (sensitive edge with 8K2
resistor)
r8 = Reclose while opening (sensitive edge with 8K2
resistor)
Partial opening
Open
Close
Step-by-step - The fi rst command is to open and the
second to close.
Sequential - The fi rst command is to open, the second to
STOP, the third to close and the fourth to STOP.