16 - Manual FA01796-IT - 04/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
GENERIC MOTOR
A1 - Motor type
0 = Generic
F46 - Number of motors
A2 - Motor test
> open the M2 leaf
< open the M1 leaf
Check that both leaves open. If they do not, invert M and N on the relevant terminal.
F2 - CX input
F3 - CY input
F72 - Limit-switch function*
OFF = Deactivated
With the limit switches deactivated, the stop point is defi ned by mechanical stops on the ground.
1 = Opening limit-switch and closing limit-switch
2 = Slowdown (Default)
3 = Opening limit-switch, closing slowdown
F73 - Input type FC/FA*
0 = N.O. (Default)
1 = N.C.
2 = N.C. for FA input, N.O. for FC input
A8 - Motor power
1 = Minimum power [up to 120W]
2 = Medium power (Default) [up to 200W]
3 = Maximum power [more than 200W]
A3 - Travel calibration
*Only with end-of-travel microswitches used.
If “A1” scrolls across the display, this means the type of motor must be set before any other parameters can be modifi ed.
If “A3” scrolls across the display, calibrate the travel. The panel does not accept motion commands, except for the motor test (A2).
Complete programming and check the warning and safety devices are working properly.
After powering up the system, the fi rst manoeuvre is always to open the gate Wait for the manoeuvre to be completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the system.