19 - Manual FA01796-IT - 04/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
F10 Gate-open warning light 0 = Warning light on (default) - The warning light stays on when the gate is moving or open.
1 = Warning light fl ashing - The warning light fl ashes every half second when the gate is opening and stays on when the gate is open.
The light fl ashes every second when the gate is closing, and remains o when the gate is closed.
F11 Encoder ON (Default)
OFF
F13 Closing thrust OFF (Default)
1 = Minimum thrust
2 = Medium thrust
3 = Maximum thrust
F16 Thrust OFF (Default)
ON
F17 Electric lock OFF (Default)
1 = From closed
2 = From open
3 = From open and closed
4 = Continue
F18 Additional light OFF (Default)
1 = Cycle light - The lamp stays on during the manoeuvre.
2 = Courtesy lamp - The light switches on when a manoeuvre starts and remains on once the manoeuvre has fi nished, for the time set
under the function [F25 Courtesy time].
F19 Automatic closure OFF (Default)
From 1 to 180 seconds
F20 Automatic closing after either partial or
pedestrian opening
OFF
1 to 180 seconds (Default 10)
F21 Pre-fl ashing time OFF (Default)
1 to 10 seconds
F23 M1 opening delay time OFF
1 to 10 seconds (Default 2)