EasyManua.ls Logo

CAME ZLX24MA - System Information and Recovery; Manoeuvre Counter Display (A5); Motor Power Configuration (A8); Firmware Version Display (H1)

CAME ZLX24MA
112 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23 - Manual FA01796-IT - 04/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
A5 Manoeuvre counter Tot = total manoeuvres - Manoeuvres performed since the operator was installed.
Par = partial manoeuvres - Manoeuvres carried out after the last maintenance.
A8 Motor power 1 = Minimum power [up to 120W]
2 = Medium power (Default) [up to 200W]
3 = Maximum power [more than 200W]
H1 FW version Use the < > arrows to show the versions of the display board and the control board one after the other.
H3 Enable password OFF (Default)
ON
Forgotten password
If you lose the password, you will need to reset the board to its factory settings. See [Factory reset].
Factory reset
Disconnect the control board from the power supply and wait for it to switch o .
Press and hold the < and > buttons, then reconnect the control board to the power supply.
Continue to press and hold the < > buttons until [ON/OFF] is displayed.
Select [ON].
Press ENTER to confi rm.
When you reset the control board, all saved users, set times, manoeuvre confi gurations and calibration operations are deleted.