8.4 Count Function
With the Count function enabled during setup of the indicator, the
function must be activated before it can be used.
Refer to section 4.14 Function Setup, the FUnC (FUnC?) parameter to
enable the Fn/ key Count function.
NOTE: This function is not available when Legal-For-trade (LFt=yes)
has been selected in setup. In addition, only one of the functions Hold,
Count, Peak Hold, Checkweigher or Live Weight can be active at a time.
8.4.1 Activate Count Function
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. Press the TARE key until the display shows CoUntX, the prompt
and status of the Count function.
4. If the setting displayed is acceptable, press the TARE key to save
it. Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
1 = Count Function Active
0 = Count Function Not Active
5. Repeatedly press the TARE key to step through the remaining
function prompts until the indicator returns to the weight display.
8.4.2 Count Function Operation
1. Press the Fn/ key. If no average piece weight has been set, the
display will show Add= 5.
2. Repeatedly press the Fn/ key to cycle through the sample sizes
5, 10, 25, 50, and 75 pieces.
3. Alternatively, press the UNITS/ key. The digit will start to flash.
4. Repeatedly press the Fn/ key until the desired value is displayed.
5. Press the UNITS/ key to select the next digit.
6. Add the number of pieces to the scale and press the TARE key.
7. The display will change to show the number of pieces on the scale.