Model 190 Installation, Technical and Operation
8400-M022-O1 Rev J
8.6 Peak Hold Function
With the Peak Hold function enabled during setup of the indicator, the
function must be activated before it can be used.
Refer to section 4.14 Function Setup, the FUnC (FUnC?) parameter to
enable the Fn/ key Hold function.
NOTE: Only one of the functions Hold, Count, Peak Hold, Checkweigher
or Live Weight can be active at a time.
8.6.1 Activate Hold Function
1. Press and hold the Fn/ key until the display blanks.
2. Once the display blanks, release the Fn/ key
3. The display will change to show PHoldX, the prompt and status of
the Peak Hold function.
4. If the setting displayed is acceptable, press the TARE key to save
it. Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
1 = Peak Hold Function Active
0 = Peak Hold Function Not Active
6. Repeatedly press the TARE key to step through the remaining
function prompts until the indicator returns to the weight display.
8.6.2 Peak Hold Function Operation
When the Peak Hold function is active, the largest weight value
measured since Peak Hold was activated (or cleared) will be stored.
1. To display the peak value, momentarily press the Fn/ key.
2. To zero the peak value, make sure there is no load on the scale and
press the ZERO key.
3. Press the NET/GROSS key to return to the weight display.